9027 30 000 0 — Instruments and apparatus for physical or chemical analysis (for example, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes: spectrometers, spectrophotometers and spectrographs using optical radiations (ultraviolet, visible, infrared)

Instruments and apparatus for physical or chemical analysis (for example, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes: spectrometers, spectrophotometers and spectrographs using optical radiations (ultraviolet, visible, infrared)

Names come in English where the EU Combined Nomenclature publishes them — chapters, headings and subheadings, whose first six digits are the same Harmonized System; deeper EAEU detail is a machine translation, marked as such. Official texts — tariff notes, measures, lists and classification rulings — are the original: customs and your broker go by that wording. Where we show a machine translation of them, it is marked; where our quality check rejected one, the Russian stays.

Machine translation. The original is the Russian text of the EAEU tariff, and customs goes by it; this translation is for understanding only and has no legal force.

Duty rate
0%

This is the base rate. A tariff quota, a preference for the country of origin and a tariff exemption lower it; anti-dumping and special duties are paid on top of it

EEC Council Decision No. 80 of 14.09.2021

Supplementary unit
шт
Item
Requirements and measures
7

None: trade defence measures — duty on top of the tariff, tariff quota.

Whether a measure applies to your goods depends on their characteristics and the shipping documents

VAT
VAT-exempt or 22%

Exempt if it is a medical device on the exemption list. Otherwise 22%.

Where it sits in the nomenclature

Section XVIII. Optical, photographic, cinematographic, measuring, checking, precision, medical or surgical instruments and apparatus; clocks and watches; musical instruments; parts and accessories thereof

  1. 90Optical, photographic, cinematographic, measuring, checking, precision, medical or surgical instruments and apparatus; parts and accessories thereof
  2. 9027Instruments and apparatus for physical or chemical analysis, e.g. polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus; instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light, incl. exposure meters; microtomes
  3. 9027 30Spectrometers, spectrophotometers and spectrographs using optical radiations, such as UV, visible, IR
  4. 9027 30 00Spectrometers, spectrophotometers and spectrographs using optical radiations (ultraviolet, visible, infrared)
  5. 9027 30 000 0you are here

Explanatory notes to heading 9027 8 paragraphs

Machine translation from Russian. The original is the EEC explanatory note, and that is what a classification dispute is argued from; the translation is for understanding and has no legal force.

9027 Instruments and apparatus for physical or chemical analysis (for example, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes: 9027 10 – gas or smoke analysis apparatus 9027 20 – chromatographs and electrophoresis instruments 9027 30 – spectrometers, spectrophotometers and spectrographs using optical radiations (ultraviolet, visible, infrared) 9027 50 – other instruments and apparatus using optical radiations (ultraviolet, visible, infrared) 9027 80 – other instruments and apparatus 9027 90 – microtomes; parts and accessories

This heading covers: (1) Polarimeters. Instruments for measuring the angle through which the plane of polarisation of a ray of light is rotated when passing through an optically active substance. They consist of a light source, an optical device containing polarising and analysing prisms, a holder for the tube in which the substance to be analysed is placed, an observation eyepiece and a measuring scale. In addition to the basic optical elements of the ordinary polarimeter, electronic polarimeters are also fitted with a photoelectric cell. (2) Half-shade polarimeters for analysing plane-polarised or elliptically polarised light. (3) Saccharimeters. These are special polarimeters designed for determining the concentration of sugar solutions. (4) Refractometers. These are instruments for determining the refractive index of liquids or solids (one of the most important constants in determining the purity of a substance). They consist essentially of a system of prisms, observation eyepieces and reading eyepieces, and a device for regulating the temperature (since this greatly affects the refractive index). They are used particularly widely in the food industry (for checking oils of vegetable origin, butter and other fatty substances, analysing jams, fruit juices, etc.), in the glass industry, in oil refineries, in biology (for measuring the protein content of blood plasma or of effluents, etc.). Most refractometers are mounted on a base or stand; others are of the hand type or may be designed for fixing to the wall of production tanks. (5) Spectrometers. These instruments are used for measuring the wavelengths of emission and absorption spectra. They consist essentially of an adjustable slit collimator (through which the ray of light to be analysed passes), one or more adjustable prisms, a telescope and a prism table. Some spectrometers (particularly those used for infra-red or ultra-violet rays) are fitted with prisms or diffraction gratings.

This category of goods includes: spectroscopes for spectra observation; spectrographs for recording the spectrum on an otographic plate or film (spectrograms); monochromators - devices for isolating a line in a linear spectrum or for isolating some parts of a continuous spectrum. This heading does not include spectroheliographs and spectrogel ioscopes used for solar observations (heading 9005); spectral projectors for the study of enlarged spectrograms projected onto a screen (heading 9008); laboratory measuring microscopes and spectrocomparators containing mikroscopes (for the comparative study of spectrograms by optical observation) (heading 9011); and spectrum analyzers for the measurement or control of electrical quantities (heading 9030). (6) Mass spectrographs and similar apparatus for analysis of top composition, etc. materials. However, this heading does not cover isotope separation calutrons (heading 8401). (7) Colorimeters. The term colorimeter refers to two different classes of instruments. One class is used to determine the color of a substance (liquid or solid) by matching its color with the color obtained from three primary colors (red, green and blue), mixed in variable but measured proportions. Colorimeters of the second class are used in chemical or bi-ochemical analysis to determine the concentration of a substance contained in a solution by comparing the color of this substance (or the color of the substance after treatment with its reagent) with the color of the colored reference plates or reference liquid. In one type of colorime of the last class, the test solution and the reference solution are contained in two glass tubes, which are examined using two prisms through the eyepiece. Some of these devices are based on the use of a photocell. In some devices of this t ipa, a paper tape is used with a reagent that changes its color after reaction with gas. These devices use two solar cells that measure color before and after reaction with gas. This group of products also includes devices for optical analysis, such as nephelometers and turbidimeters (to determine the turbidity of solutions), absorbiometers, fluorimeters (to determine fluorescence, widely used in the analysis of the content of vitamins, alkaloids, etc.), blancometers and densitometers (specially used to measure the degree of whiteness, opacity and shine of paper mass, etc.). (8) Gas or smoke analysis apparatus. They are used to analyze combustible gases or combustion by-products (burnt gases) in coke batteries, gas generators, blast furnaces, etc., in particular to determine the content of carbon dioxide, carbon monoxide, oxygen, hydrogen, nitrogen or hydrocarbons. Electrical devices for gas or smoke analysis are mainly designed to determine and measure the content of the following gases: carbon dioxide, carbon monoxide and hydrogen, oxygen, hydrogen, nitrogen, sulfur dioxide, ammonia. Some of these devices or apparatuses volometrically detect the gases absorbed by the corresponding chemicals or burnt. These include: (i) Orsian apparatus consisting mainly of an aspiration bottle, one or more absorption flasks and a measuring burette; (ii) incinerator or explosion apparatus. They are additionally equipped with a pipette for combustion or explosion (platinum capillary tube, platinum or palladium wire tube with induction ignition, etc.).

These different types of apparatus can also be used in combinations. Other models work on the basis of measuring the density and degree of condensation of the distillation fraction (cracking) or on the following principles: (i) the thermal conductivity of gases; (ii) the thermal effect of combustible gases on electrodes (for example, carbon monoxide and hydrogen monoxide in the discharge gases); (iii) selective absorption of ultraviolet, infrared or microwave radiation by a gas; (iv) differences in the magnetic permetricity of gases; (v) chemiluminescent reactions of gases with suitable auxiliary gas constituents; (vi) ionization of hydrocarbons in hydrogen in a liquid oxygen (vi) for a reaction (videliquiferous gas (vide) in a chemical reaction (vide) with a gas (vide) in a chemical reaction (videliquiferous gas) and (viii) in a chemical reaction (viii) in a chemical reaction (videliquiferred) in a reaction (viii) with a gas (viii) in a gas (viii) in a chemical reaction (videliqui It should be noted that this heading includes gas or smoke analysis apparatus intended for use in industrial processes (i.e., directly connected to furnaces, gas generators, etc.). But apparatus consisting merely of laboratory glassware falls in heading 7017. (9) Electronic smoke detectors used in furnaces, stoves, etc., for example, in which a beam of light (or infrared rays) is directed to a solar cell. In accordance with the density of the smoke, the passage of this beam through the smoke causes a change in the current in the circuit of the photocell, thereby affecting the graduated indicator or recording system, and in some cases the regulating valve. These apparatuses may be equipped with an alarm device. Electronic smoke detectors equipped exclusively with a signaling device fall in heading 8531. (10) Flammable gas detectors and other detectors (e.g. carbon dioxide). They contain a portable apparatus for detecting gas in mines or tunnels, for detecting leaks in highways, etc. (11) Apparatus for analyzing dust in gases. They work by passing a given amount of gas through the filter disc and weighing the filter before and after the test. This category includes tindallometers used to measure the amount of dust in the air and to test dust masks, filters, etc. They consist of a dust chamber covered with black glass, a light source, a photometric head with a prismatic measuring device and a graduated circular scale for measuring rotational angles. (12) Oxygen meters for determining the amount of dissolved oxygen in liquids using a polarimetric element or by chemical reaction of thallium with dissolved oxygen (measurement of changes in electrolytic conductivity).

(13) Polarographic analyzers for determining components of liquids, e.g. traces of dissolved metals in water, by measuring and calculating the current/resistance ratio for electrodes immersed in solution. (14) Moisture-chemical analyzers for the determination of inorganic or organic components of liquids, e.g. traces of metals, phosphates, nitrates, chlorides or integral parameters such as "chemical oxygen demand" and "total organic carbon content". The analyzer consists of a device for preparing samples, an analysis unit, for example, with ion-sensitive electrodes, photometers or polarographs and, in automatic analyzers, a control unit. (15) Viscometers and similar devices used to determine viscosity (i.e. internal friction in a liquid). The principle of their operation can be based on: (i) the measurement of the time required for the passage of a liquid through a capillary tube under constant pressure (for example, the temple osimeters of Oswald, Engler, etc.); (ii) the effect of friction between a solid and a liquid; or (iii) the measurement of the time the ball falls in a liquid. (16) Polariscopes (stress indicators). These devices measure internal stresses in the glass (for example, arising from quenching, annealing, welding, etc., which can lead to the fragility of the glass). They consist of a chamber containing an electric lamp, a light scattering device, a polarizer and a polarizing telescope. Stresses in glass are detected in the form of bright rainbow areas. (17) Expansion meters measure the expansion or contraction of steel, metal alloys, coke, etc. from temperature changes. Most of these recording devices are of a recording type (mechanical diagram entry or photographic registration). (18) Apparatuses for determining porosity or permeability (relative to water, air, other gases, etc.), known as porosimeters or permeameters (not to be confused with devices for measuring the magnetic permeability of substances). They are used for paper, textile fibers, fabrics, plastics, leather, sand, etc. (19) Instruments for measuring surface tension or interlayer stress in liquids (e.g. dynamo scales). Surface tension in liquids is usually determined by one of the following three indicators: the mass of the drop falling from a capillary tube of a given diameter (or the number of drops that make up a known volume) (the method of falling a drop); the height of the liquid column in the capillary of a given diameter (capillary method); or the force necessary to remove the ring from the surface of the liquid. (20) Instruments for measuring osmotic pressure (osmometers), that is, the pressure that occurs when two mixing liquids are separated by a membrane that is partially, but not equally, permeable to them. (21) Equipment for testing petroleum products and their products (e.g. bitumen, asphalt, tar, etc.). This includes devices for determining the flash, hardening, fluidity, droplet formation, etc. of petroleum products, as well as the melting temperature of paraffins, water content, sulfur, contaminants, consistency of lubricants and tars, evaporation and solidification temperatures, etc.

(22) pH meters and rH meters (redox potential sensors) pH sensors are used to measure the acidity or alkalinity of a solution or mixture (distilled water is the neutrality standard). RH sensors are used to measure the oxidative or reducing force of a solution. These devices operate on a variety of different principles; the most common type uses an electrometric system in which the electrodes determine a potential difference proportional to the pH or rH of the solution. In addition to measuring, such instruments can also be used for automatic regulation. (23) Devices based on the principle of electrophoresis .The action of these devices is based on a change in concentration when direct current passes through the solution. Electrically charged particles migrate at different speeds according to the nature of matter. These devices are usually connected to a photometric device consisting of a photovoltaic cell and a milliammeter graduated directly in units of optical density. They are used to analyze various solutions (proteins, amino acids, etc.), to study substances such as plasma, hormones, enzymes, viruses, etc., and to study the phenomenon of polymerization. (24) Chromatographs (such as gas, liquid, ion-exchange and thin-layer chromatographs) to determine the components of a gas or liquid. In analysis, the gas or liquid is passed through columns or thin layers of the absorbent and then measured using a detector. The characteristics of the analyzed gases or liquids are determined by the time they pass through the columns or thin layers of the absorbent, while the number of different components analyzed is determined by the level of the detector output signal. (25) Electron titrometers, which use measuring electrodes for titration of water, silver salts, halogens, etc. (26) Analytical instruments, sometimes called "humidity meters for solids", whose principle of operation is based on the measurement of the dielectric constant, electrical conductivity, absorption of electromagnetic energy or infrared radiation of substances. (27) Specific ale metering of ctroconductivity to determine electrolytic specific conductivity or concentration of salts, acids or bases dissolved in a liquid. (28) Densitometers and microdensitometers on photocells used to measure the density of spectral photographs and to analyze any phenomena recorded on the photographic emulsion. (29) Photometers. Instruments for measuring the intensity of light. The measured light and the standard light source shall be positioned so that they illuminate a given surface with equal intensity. If, instead of comparing two light intensities, a comparison is made for their respective spectra, the instrument used in that case is known as a spectrophotometer. Photometers are widely used for various optical processes and analyses (for example, to determine the degree of concentration, degree of shine or transparency of solids; degree of exposure of photographic plates or films (densitometers); color depth of transparent or opaque solids or solutions).

Certain photometers used in photography or cinematography are known as exposure meters and are used for measuring the exposure time or for determining the lens aperture. (30) Luxmeters (used for determining the illumination in lux produced by a light source). (31) Calorimeters. These measure the quantity of heat absorbed or released by a solid, a liquid or a gas. The main categories are as follows: (A) Ice calorimeters (Bunsen calorimeters), based on the change in volume produced by melting ice. They consist of a test tube surrounded by ice and immersed in a tank of water, and of a graduated tube containing mercury. (B) Heating calorimeters (Berthelot calorimeters), based on the principle of heat transfer. They consist essentially of a calorimetric vessel filled with water, placed inside a tank also filled with water; they are fitted with stirrers and thermometers. The two types of calorimeter currently in use are based on the same principle, namely: (i) calorimeters for determining the specific heat of gases or liquid fuels. In these applications water circulates through a section in which a quantity of the gas or liquid is burnt. The difference in water temperature at the inlet and the outlet is measured; (ii) calorimetric bombs. These are used for determining the heat of combustion of materials. They consist essentially of a steel vessel (bomb) containing a known quantity of the solid or liquid to be tested, together with oxygen under pressure. By means of a suitable device the sample is burnt in the oxygen, and the quantity of heat released is determined by placing the bomb in a water calorimeter. The heading also covers calorimeters for industrial use; these are installed on generators producing gas of a given calorific value. But if they are connected to regulating apparatus for maintaining the calorific value of mixed gases at the required level, they are excluded from this heading (generally heading 9032). (32) Cryoscopes and ebullioscopes, other than instruments having the character of laboratory glassware (heading 7017). (33) Instruments and apparatus used in medical laboratories for in vitro diagnosis. The heading also covers microtomes – instruments used in microscopy for cutting very thin sections of known thickness from the substances to be examined. Microtomes may be of various types, e.g., hand type (resembling a straight razor), rotary type, sliding carriage type (horizontal or inclined plane). PARTS AND ACCESSORIES Subject to the provisions of Notes 1 and 2 to this Chapter (see the General Explanatory Note), the heading also covers parts and accessories identifiable as being suitable for use solely or principally with the instruments and apparatus referred to above. The heading also excludes:

(a) laboratory equipment of refractory materials (retorts, crucibles, mortars, dishes, baths and similar articles) (heading 6903) and similar articles of other ceramic materials (heading 6909); (b) laboratory glassware (heading 7017) (see further below); (c) microscopes (heading 9011 or 9012); (d) precision balances (heading 9016); (e) X-ray and other apparatus (heading 9022); (f) demonstration apparatus of heading 9023; (g) machines and appliances for testing certain materials (heading 9024); (h) hydrometers, thermometers, hygrometers and similar instruments of heading 9025, whether or not intended for laboratory use; (ij) apparatus of heading 9026. Classification of articles which may fall either in this heading or in heading 7017 (laboratory glassware). In these cases classification is determined by the following considerations: (1) If the article has the essential character of an article of glass (whether or not graduated, whether or not calibrated, and whether or not having subsidiary stoppers, joints, etc., of rubber, etc.), it is not to be classified in this heading, even if it is commonly known as a particular instrument or apparatus. (2) Instruments usually cease to have the essential character of glassware if they consist partly of glass but mainly of other materials, or if they consist of glass parts enclosed in or permanently fixed to mountings, stands, cases, etc. (3) The combination of glass parts with measuring instruments (e.g., manometers, thermometers) may in practice justify regarding such instruments as falling in this heading. Accordingly, the following instruments in the form of a simple calibrated glass article fall in heading 7017: butyrometers, lactobutyrometers and similar instruments for testing dairy products; albuminometers and ureometers; eudiometers; volumenometers; nitrometers, Kipp's or Kjeldahl apparatus and similar apparatus; calcimeters; cryoscopes and ebullioscopes for determining molecular weight, etc. This heading also excludes machines and apparatus (whether or not electrical) of a type classified in Section XVI, even though by reason of their low output, small size and general construction they are obviously intended for use in laboratories (e.g., for the preparation or treatment of samples). This heading therefore excludes furnaces, autoclaves, drying or steam ovens or cabinets; desiccators; crushers and mixers; centrifuges; distilling apparatus, presses; filters and filter presses; stirrers, etc. Similarly, heating apparatus (Bunsen burners, steam baths, etc.), tools, laboratory furniture (e.g., laboratory benches, microscope tables, fume cupboards) and brushes fall in their appropriate headings (Section XV, Chapter 94 or 96).

Official text adopted by a Recommendation of the EEC Board

Notes to chapter 90 — Optical, photographic, cinematographic, measuring, checking, precision, medical or surgical instruments and apparatus; parts and accessories thereof 8 items

Notes

Machine translation. The original is the Russian text of the EAEU tariff, and customs goes by it; this translation is for understanding only and has no legal force.

1. This group does not include:

(a) articles used in machinery, appliances or for other technical purposes, made of vulcanised rubber other than hard rubber (heading 4016), natural or composite leather (heading 4205) or textile material (heading 5911);

(b) support belts or other supporting articles of textile materials, the purposeful effect of which on the supported or fixed organ is only due to their elasticity (for example, bandages for pregnant women, chest bandages, abdominal bandages, joint or muscle locks) (Section XI);

(c) refractory articles of heading 6903; ceramic articles for laboratory, chemical or other technical purposes of heading 6909;

(d) optically raw glass mirrors of heading 7009 or of base or precious metal mirrors other than optical elements (heading 8306 or Chapter 71);

(e) the goods of heading 7007, 7008, 7011, 7014, 7015 or 7017;

(f) parts of general use referred to in Note 2 to Section XV of base metals (Section XV) or similar products of plastics (Chapter 39); however, articles specifically intended for use exclusively in implants used in medicine, surgery, dentistry or veterinary medicine are to be classified in heading 9021;

(ж) насосы с измерительными приборами товарной позиции 8413; счетное или контрольное оборудование, приводимое в действие силой тяжести взвешиваемого груза, или поставляемые отдельно разновесы для весов (товарная позиция 8423); подъемное или погрузочно-разгрузочное оборудование (товарные позиции 8425 – 8428); машины всех видов для резки бумаги или картона (товарная позиция 8441); приспособления для регулирования положения обрабатываемых деталей или инструмента на станках или водоструйных резательных машинах товарной позиции 8466, включая приспособления с оптическими элементами для считывания показаний приборов (например, «оптические» делительные головки), но за исключением тех устройств, которые сами по себе являются исключительно оптическими приборами (например, юстировочные телескопы); счетные машины (товарная позиция 8470); клапаны и другая арматура товарной позиции 8481; машины и аппаратура (включая аппаратуру для проецирования или нанесения рисунка маски на сенсибилизированные полупроводниковые материалы) товарной позиции 8486;

(з) прожекторы или фары, используемые на велосипедах или моторных транспортных средствах (товарная позиция 8512); портативные электрические фонари товарной позиции 8513; кинематографические аппараты для записи, воспроизведения или повторной записи звука (товарная позиция 8519); звуковые головки (товарная позиция 8522); телевизионные камеры, цифровые камеры и записывающие видеокамеры (товарная позиция 8525); радиолокационная аппаратура, радионавигационная аппаратура или радиоаппаратура дистанционного управления (товарная позиция 8526); соединители для волокон оптических, волоконно-оптических жгутов или кабелей (товарная позиция 8536); цифровые аппараты управления товарной позиции 8537; лампы герметичные направленного света товарной позиции 8539; волоконно-оптические кабели товарной позиции 8544;

(ij) floodlights or headlights of heading 9405;

(k) articles of Chapter 95;

(l) monopores, bipeds, tripods and similar articles of heading 9620;

(m) volume measuring tanks classified by the material from which they are made; or

(n) coils, reels or similar carriers (which are to be classified according to the material of which they are made, for example, in heading 3923 or in section XV).

2. Subject to the provisions of Note 1, parts and accessories to machinery, apparatus, tools or articles in this Chapter shall be classified according to the following rules:

(a) parts and accessories which are goods falling in one of the headings of this Chapter or of Chapter 84, 85 or 91 (other than heading 8487, 8548 or 9033) are in all cases classified in the relevant headings;

(b) other parts and accessories intended to be used exclusively or principally in a particular type of machine, tool or apparatus or in several machines, tools or apparatus falling under the same heading (including machinery, tools or apparatus of heading 9010, 9013 or 9031) are included with those machines, tools or apparatus;

(c) all other parts and accessories fall in heading 9033.

3. Notes 3 and 4 to section XVI also apply to this chapter.

4. Heading 9005 does not include telescopic sights for mounting weapons, telescopic periscopes for submarines or tanks, or sight-tubes fitted to machines, devices, instruments or apparatus of this Chapter or Section XVI; such telescopic sights and sight-tubes are classified in heading 9013.

5. Measuring or control optical devices, devices or machines which, but for this note, could be included in both heading 9013 and heading 9031 are classified in heading 9031.

6. For the purposes of heading 9021, the term “orthopedic devices” means devices for:

prevention or correction of bodily deformities; or

Supporting or fixing body parts after illness, surgery, or injury.

Orthopedic appliances include shoes and special insoles made for the correction of orthopedic conditions, provided that they are either (1) made to order standards, or (2) mass-produced, represented by one object and not in pairs and designed to be equally suitable for any foot.

7. Heading 9032 covers only:

(a) instruments and devices for the automatic control of the flow rate, level, pressure or other variable parameters of liquids or gases, or for the automatic control of temperature, whether or not their action is based on an electrical phenomenon varying according to the parameter to be regulated, which are designed to bring this parameter to the desired value and to keep it stable against disturbances, constantly or periodically measuring the actual value; and

(b) automatic regulators of electrical quantities and devices or devices for the automatic regulation of non-electrical quantities, the operation of which is based on an electrical phenomenon varying depending on the parameter to be regulated, which are designed to bring this parameter to the desired value and keep it stable from disturbances, constantly or periodically measuring the actual value.

Additional note

Machine translation. The original is the Russian text of the EAEU tariff, and customs goes by it; this translation is for understanding only and has no legal force.

1. Термин «электронные» в подсубпозициях 9015 10 100 0, 9015 20 100 0, 9015 30 100 0, 9015 40 100 0, 9015 80 110 0, 9015 80 190 0, 9024 10 110 0, 9024 10 130 0, 9024 10 190 0, 9024 80 110 0, 9024 80 190 0, 9025 19 200 0, 9025 80 400 0, 9026 10 210 0, 9026 10 290 0, 9026 20 200 0, 9026 80 200 0, 9027 10 100 0, 9030 20 910 0, 9030 33 100 0, 9030 89 300 0, 9031 80 320 0, 9031 80 340 0, 9031 80 380 0 и 9032 10 200 0 означает приборы и аппараты, которые включают в себя одно или несколько изделий товарной позиции 8540, 8541 или 8542. Однако это не должно относиться к изделиям товарной позиции 8540, 8541 или 8542, функцией которых является исключительно выпрямление тока или которые входят в состав блока питания приборов или аппаратов.

Classification rulings for this code (4)

Machine translation from Russian. The original is the Russian wording of the ruling, and customs goes by it; this translation is for understanding only and has no legal force.

A detector, functionally a spectrometer, designed to analyze the physical or chemical properties of a sample of the studied substances absorbing ultraviolet and visible radiation, by measuring the wavelengths of the spectra and representing the measured value in the form of a proportional electrical signal transmitted to the data processing system and the control computer (not included in the package) for the subsequent construction of the chromatogram.

Full description

It is used as a discrete unit when completing block systems of high-performance liquid chromatography (HPLC), created depending on various analytical tasks.

The main components of the detector: 1) the radiation module of the spectral range 190 - 800 nm (consists of two lamps - deuterium and tungsten) serves to direct light to the sample of the substance being in the ditch; 2) the optical system (diffraction grating) extends the solid light from the radiation source into a spectrum between 190 and 800 nm; 3) the signal recording module (diode matrix) registers the light intensity in the entire spectral region (each diode registers light in a narrow range of wavelengths), converts the optical signal into an electric one and transmits it to the main board;

(4) the master board controls and controls the operation of the detector components; 5) the communication module board connected to the main board is designed to provide data transmission through the interfaces: USB, CAN, REMOTE, LAN; (6) electrical supply modules for lamps and the main control board. Supply kit: packaging box, in which the detector and the following accessories are located together: data transmission cable - 1 pc.; backpressure tube for flow cuvette - 1 pc.; polymer tubes with external diameter 1/16" (internal diameters: 0.01" and 0.007") - 2 pcs., connector-3 pcs.; fuse - 2 pcs.; power adapter - 1 pc.; data transmission cable - 2 pcs., wireless router. - 1 pc.; manual - 1 pc.

Overall dimensions of the detector (D x Sh x V) 500x386x165 mm, weight 15 kg.

GRI 1 and 6

A detector, functionally a spectrometer, designed to analyze the physical or chemical properties of a sample of the studied substances absorbing ultraviolet (hereinafter - UV) and visible radiation, by measuring the wavelengths of the spectra and representing the measured value in the form of a proportional electrical signal transmitted to the control computer and other data processing systems (not included in the package) for the subsequent construction of the chromatogram.

Full description

It is used as a discrete unit when completing block systems of high-performance liquid chromatography (HPLC), created depending on various analytical tasks.

The main components of the detector: (1) the deuterium lamp emits UV light between 190 and 422 nm; (2) the tungsten lamp emits visible light between 422 and 900 nm; (3) the focusing mirror fixes the radiation from the light sources on the inlet slit; (4) the inlet gap limits the bandwidth of the monochromator; 5) the filter assembly (consists of three filters switched by engine rotation) covers the wavelength range from 190 to 900 nm, removing scattered light and secondary spectrum; (6) the monochromator divides the beam into monochromatic light of different colours;

(7) the beam divider divides the light beam into two beams, one of which is directed to the photodiode of the analytical channel through the flow cuvette and the other directly to the photodiode of the comparison channel; 8) a flowing ditch through which the analyte flows, where it is exposed to monochromatic radiation and absorbs light according to its inherent properties; 9) the photodiode module is used to receive the optical signal and convert it into an electrical signal (the module includes two photodiodes: the analytical channel photodiode and the comparison channel photodiode); 10) preamplifier circuit: converts the electrical signal of the photodiode into a digital one and transmits it into software to the control computer and other equipment;

(11) a display for displaying the state of the device; (12) the main control panel controls the operation of the various components of the detector; 13) the connector panel connected to the main control board is designed to ensure the transmission of input and output control signals through the interfaces: CAN, RS232, REMOTE, LAN; (14) electrical supply charge. Supply kit: packaging box, in which the detector and the following accessories are located together: data transmission cable - 1 pc; backpressure tube for flow cuvette - 1 pc.; polymer tube with external diameter 1/16" (internal diameter 0.007") - 1 pc.; connector - 2 pcs.; silicone drain tube - 1 pc.; fuse - 1 pc.; manual for operation - 1 pc.

The overall dimensions of the detector (D x Sh x V) 500 x 385 x 165 mm, weight 15 kg.

GRI 1 and 6

Instrument for photometric, spectral (qualitative) and quantitative analysis of liquid organic solvents by measuring the spectral coefficient of directional transmission and the spectral optical density of the studied sample in the wavelength range of ultraviolet and visible spectra of optical radiation.

Full description

The principle of operation is based on a comparison of the spectra of two light fluxes of monochromatic light, one of which passed through the sample under study, the other through the reference. Distilled water is used as a reference sample. The device has a desktop version, consists of optical-mechanical and electronic nodes located in a single housing, is equipped with a 7-inch TFT-display for displaying settings of parameters and measurement results; keyboard; compartment for samples; compartment for light source; electronic module for processing measurement results using software;

USB-connector for connecting USB-drive (not included in the supply); connector RJ-45 to connect to the local network; power connector. To decompose optical radiation into the spectrum, a monochromator is used, consisting of an input and output slits, collimator and chamber lenses, a diffraction grating. As light sources are used lamps - tungsten type 12v20wg4 with a range of optical radiation 400 -1100 nm and deuterium type with a range of optical radiation 185 - 400 nm, as receivers - photodiodes that convert an optical signal into an electric one.

In photometric measurement, the device measures the optical density (OP), the transmittance and reflection coefficient of the studied sample at a given wavelength with the subsequent construction of the spectrum of flux relations. When measuring the spectrum, the OP, the transmittance and reflection coefficient of the sample at each wavelength within a given range are measured in accordance with a given interval and scanning speed with the subsequent construction of the spectrum of relations of optical radiation fluxes that passed through the studied and reference samples.

In quantitative analysis, the measured value of the OP of the studied sample is compared with the value of the concentration of the reference sample, a curve of the dependence of the OP on the concentration is constructed with the subsequent calculation of the concentration of the studied sample according to the Lambert-Beer law, according to which the absorption of light by the sample is positively proportional to the concentration of the substance. The results of spectral analysis are reflected on the device display, stored on a USB drive or transmitted to a computer (not included in the delivery) for subsequent processing, visualization, storage.

The power supply of the device is carried out from the alternating current network. Technical specifications: spectral bandwidth - 0.5 nm, 1 nm, 2 nm, 4 nm (4 scales); wavelength range - 190÷1100 nm; accuracy of wavelength: ± 0.3 nm; repeatability of wavelength: 0.1 nm; photometric range: 3.5 OP; photometric noise: ± 0.00005 OP; Display resolution - 800x480; supply voltage: 100~240 V/50÷60 Hz.

Overall dimensions: (DhShV): 550 x 550 x 220 mm. Weight: 25 kg.

GRI 1 and 6

A detector functionally representing a spectrometer designed to analyze the physical or chemical properties of a sample of the studied substances absorbing ultraviolet (hereinafter - UV) radiation by measuring the wavelengths of the luminescence spectra and representing the measured value in the form of a proportional electrical signal transmitted to the processing system for the subsequent construction of the chromatogram.

Full description

It is used as a discrete unit when completing block systems of high-performance liquid chromatography (HPLC), created depending on various analytical tasks.

The main components of the detector: (1) the xenon lamp emits UV light in the range of 200 to 650 nm, affecting the sample of the substance under study; 2) optical system - diffraction grating spreads the light from the radiation source into a spectrum in the range from 200 to 650 nm; 3) a filter which does not transmit the excitation rays; 4) a display panel consisting of a screen and LEDs, through the operation of which information about the current state of the device is reflected (the state of the radiation source, the wavelength of fluorescence excitation on the selected channel, the current selected channel, the channel number (only when measuring at several wavelengths), the wavelength of the current selected channel, the value of the fluorescence intensity);

(5) the keyboard through which the detector is controlled; 6) sockets of the output analog signal for connection of recorder, integrator, etc.; 7) connectors for connection to the system controller and for connection of external devices. Supply kit: packaging box in which the detector and accessories are located together including: signal cable - 2 pcs.; power cable - 1 pc., optical cable - 1 pc., event cable - 1 pc., polymer tubes with an external diameter of 1.6 mm (internal diameters: 0.25 mm, 0.3 mm) - 2 pcs., drain - 2 pcs., drain adapter - 1 pc., operation manual - 1 pc.

GRI 1 and 6

What import requires

Russian bans and restrictions

May apply

Whether a measure applies to your goods is determined by the provisos in the “code” column. Measures are taken from the register as of the date the act was published; the act is named on every line

  • 9027 (за исключением 9027 90 500 0, 9027 90 800 0)Out of RussiaProhibited

    Отдельные виды товаров — временный запрет на вывоз

    Приборы и аппаратура для физического или химического анализа (например, поляриметры, рефрактометры, спектрометры, газо- или дымоанализаторы); приборы и аппаратура для измерения или контроля вязкости, пористости, расширения, поверхностного натяжения или аналогичные; приборы и аппаратура для измерения или контроля количества тепла, звука или света (включая экспонометры); микротомы

    Постановление Правительства РФ от 09.03.2022 № 311 — until Dec 31, 2027

  • 9027 30 000 0Out of RussiaPermit required

    Лабораторное, добычное, геологоразведочное, геофизическое оборудование

    Спектрометры, спектрофотометры и спектрографы, основанные на действии оптического излучения (ультрафиолетового, видимой части спектра, инфракрасного)

    Постановление Правительства РФ от 09.03.2022 № 312 — until Dec 31, 2027

Veterinary and sanitary control

Goods fall under supervision by their type and characteristics

  • Sanitary and epidemiological supervision (control)

    rule for the whole chapter 90
    Продукция машиностроения и приборостроения производственного, медицинского и бытового назначения, кроме запасных частей к транспортным средствам и бытовой технике (за исключением контактирующих с питьевой водой и пищевыми продуктами); Средства индивидуальной защиты; Иная продукция (товары), в отношении которой одним из государств – членов Евразийского экономического союза введены временные санитарные меры

    Решение Коллегии Евразийской экономической комиссии от 17.09.2019 № 154

Conformity assessment

May apply

Whether the goods fall under a regulation depends on their name and characteristics. Check them against the list

  • ТР ТС 010/2011Safety of machinery and equipment
    • Оборудование гаражное для автотранспортных средств и прицепов — certificate of conformity (part of the heading)
  • Постановление № 2425Единый перечень продукции: сертификация и декларирование в РФ
    • Электрооборудование рудничное нормальное — certificate of conformity (part of the heading) · ГОСТ 30852.20-2002

Checked: the consolidated list of Government Decree No. 2425 and the lists of 42 technical regulations out of 52 adopted. The others have no list by HS code, so see the full list of regulations.

Dual use

Expert review needed

Goods fall under control by their technical characteristics, regardless of the code. Supplying without a licence when one is required is a criminal offence

  • Раздел 1 · Категория 1. Специальные материалы и связанные с ними оборудование и снаряжение

    • Системы, оборудование и компоненты → Защитное снаряжение, аппаратура систем обнаружения и комплектующие изделия, не специально разработанные для военного применения:1.1.4.4 Электронное оборудование и его компоненты, разработанные для автоматического обнаружения или распознавания наличия следов взрывчатых веществ (ВВ) с использованием методов их обнаружения (например, поверхностной акустической волны, спектрометрии подвижных ионов, в том числе с дифференциальной подвижностью, масс-спектрометрии)

Checked: one control list of six: dual-use goods (Russian Government Decree No. 1299 of 19.07.2022). The other five lists (nuclear, nuclear dual-use, missile, chemical, biological) are not checked here.

EAEU non-tariff regulation

Unified list of non-tariff measures (EEC Board Decision No. 30 of 21.04.2015). List entries selected by code

  • 2.16licensing regimeon import and exportpartial match

    Радиоэлектронные средства и (или) высокочастотные устройства гражданского назначения, в том числе встроенные либо входящие в состав других товаров

    1 list entry

    включающие в себя высокочастотные генераторы

Tariff preferences

The code is on the EAEU list of preferential goods: for goods originating in a beneficiary country the duty is lower

Least developed countrieszero rate0%
46 countries

Burkina Faso, Guinea, Eritrea, Congo - Kinshasa, Timor-Leste, Afghanistan, Mauritania, Yemen, Cambodia, Lesotho, Laos, Bangladesh, Nepal, Tanzania, Palestinian Territories, Angola, Benin, Burundi, Haiti, Gambia, Guinea-Bissau, Djibouti, Zambia, Kiribati, Liberia, Madagascar, Malawi, Mali, Mozambique, Niger, Rwanda, Senegal, Myanmar (Burma), Sudan, Sierra Leone, Uganda, Chad, South Sudan, Syria, Solomon Islands, Comoros, Togo, Tuvalu, Ethiopia, Somalia, Central African Republic

The preference requires a document of origin and compliance with the direct consignment rule; customs checks the right to it at declaration.

Payments on import

Duty for this code: 0%. On top of the duty, on import into Russia you pay VAT of 22% (unless the goods are VAT-exempt) of the customs value including the duty (Article 160 of the Tax Code) and the customs processing fee — RUB 73,860 per declaration: the goods are on the radio-electronics list (Annex 1 to Government Decree No. 1637). Customs value: the price of the goods, delivery to the border, local costs.

Import VAT in EAEU countries

  • Russia22%
  • Kazakhstan16%
  • Belarus20%
  • Armenia20%
  • Kyrgyzstan12%

Standard rate; each country has reduced rates and exemptions for some goods. The duty for the code above is the union one, the same for all

May be VAT-exempt

The exemption under list No. 1042 applies if the goods match the description and are registered as a medical device:

  • 9027 — Приборы для функциональной диагностики измерительные 94 4100 (комплексы аппаратуры для передачи электрокардиограмм по телефонному каналу; кардиокомплексы; приборы для измерения биоэлектрических потенциалов; средства измерения массы, силы, энергии, линейных и угловых величин, температуры; приборы для измерения давления; приборы для измерения частоты, скорости, ускорения, временных интервалов и перемещений; приборы для исследования звуковых колебаний в органах человека; приборы для измерения объема и газового состава вдыхаемого и выдыхаемого воздуха и крови; генераторы сигналов диагностические; измерительные установки, комплексы, сигнализаторы, регистраторы, индикаторы)
  • 9027 — Приборы и аппараты для медицинских лабораторных исследований 94 4300 (анализаторы состава и свойств биологических жидкостей медицинские; приборы и аппараты для санитарно-гигиенических и бактериологических исследований измерительные; приборы и аппараты для клинико-диагностических лабораторных исследований, кроме анализаторов; приборы и аппараты для санитарно-гигиенических и бактериологических исследований, кроме измерительных; комплексы и комплекты (наборы) для клинико-диагностических лабораторных исследований; комплексы и комплекты (наборы) для санитарно-гигиенических и бактериологических исследований; приборы и аппараты вспомогательные для клинико-диагностических, санитарно-гигиенических и бактериологических исследований общего назначения)

The right code is in the HS code search.