9018 90 840 9 — Instruments and appliances used in medical, surgical, dental or veterinary sciences, including scintigraphic apparatus, other electro-medical apparatus and sight-testing instruments: other instruments and appliances: other: other

Instruments and appliances used in medical, surgical, dental or veterinary sciences, including scintigraphic apparatus, other electro-medical apparatus and sight-testing instruments: other instruments and appliances: other: other

Names come in English where the EU Combined Nomenclature publishes them — chapters, headings and subheadings, whose first six digits are the same Harmonized System; deeper EAEU detail is a machine translation, marked as such. Official texts — tariff notes, measures, lists and classification rulings — are the original: customs and your broker go by that wording. Where we show a machine translation of them, it is marked; where our quality check rejected one, the Russian stays.

Machine translation. The original is the Russian text of the EAEU tariff, and customs goes by it; this translation is for understanding only and has no legal force.

Duty rate
0%

This is the base rate. A tariff quota, a preference for the country of origin and a tariff exemption lower it; anti-dumping and special duties are paid on top of it

EEC Council Decision No. 80 of 14.09.2021

Supplementary unit
шт
Item
Requirements and measures
6

None: dual use, trade defence measures — duty on top of the tariff, tariff quota.

Whether a measure applies to your goods depends on their characteristics and the shipping documents

VAT
VAT-exempt or 22%

Exempt if it is a medical device on the exemption list. Otherwise 22%.

Where it sits in the nomenclature

Section XVIII. Optical, photographic, cinematographic, measuring, checking, precision, medical or surgical instruments and apparatus; clocks and watches; musical instruments; parts and accessories thereof

  1. 90Optical, photographic, cinematographic, measuring, checking, precision, medical or surgical instruments and apparatus; parts and accessories thereof
  2. 9018Instruments and appliances used in medical, surgical, dental or veterinary sciences, incl. scintigraphic apparatus, other electro-medical apparatus and sight-testing instruments, n.e.s.
  3. 9018 90Instruments and appliances used in medical, surgical or veterinary sciences, n.e.s.
  4. 9018 90 84Instruments and appliances used in medical, surgical or veterinary sciences, n.e.s.
  5. 9018 90 840 9you are here

Compare the description of your goods with the neighbouring codes on the subheading line above.

Explanatory notes to heading 9018 12 paragraphs

Machine translation from Russian. The original is the EEC explanatory note, and that is what a classification dispute is argued from; the translation is for understanding and has no legal force.

9018 Instruments and appliances used in medical, surgical, dental or veterinary sciences, including scintigraphic apparatus, other electro-medical apparatus and sight-testing instruments (+): – Electro-diagnostic apparatus (including apparatus for functional exploratory examination or for checking physiological parameters): 9018 11 – – Electro-cardiographs 9018 12 – – Ultrasonic scanning apparatus 9018 13 – – Magnetic resonance imaging apparatus 9018 14 – – Scintigraphic apparatus 9018 19 – – Other 9018 20 – Ultra-violet or infra-red ray apparatus – Syringes, needles, catheters, cannulae and the like:

9018 31 – – syringes, with or without needles 9018 32 – – tubular metal needles and suture needles 9018 39 – – other – other instruments and appliances, used in dental sciences: 9018 41 – – dental drill engines, whether or not combined on a single base with other dental equipment 9018 49 – – other 9018 50 – other ophthalmic instruments and appliances 9018 90 – other instruments and appliances

This heading covers a very wide range of instruments and appliances which, in the majority of cases, are used only in professional practice (e.g., by physicians, surgeons, dentists, veterinary surgeons, midwives), either to make a diagnosis, to prevent or treat illness, or to operate, etc. Instruments and appliances for anatomical work or for autopsies, dissection, etc., are also included, as are, under certain conditions, instruments and appliances for dental laboratories (see Part (II) below). The instruments of this heading may be made of any material (including precious metals). This heading excludes: (a) sterile catgut and other sterile suture materials, sterile laminaria and sterile laminaria tents (heading 3006); (b) diagnostic or laboratory reagents of heading 3822; (c) hygienic or pharmaceutical articles of heading 4014; (d) laboratory, pharmaceutical or hygienic glassware of heading 7017; (e) sanitary ware of base metal (in particular, headings 7324, 7418 and 7615); (f) manicure or pedicure sets and instruments (heading 8214); (g) carriages for disabled persons (heading 8713); (h) spectacles, goggles and similar optical articles, corrective, protective or other (heading 9004); (ij) cameras (heading 9006), unless they are permanently built into instruments or appliances of this heading; (k) microscopes, etc., of heading 9011 or 9012; (l) disc calculators used to calculate lung function, body mass index, etc., of heading 9017; (m) mechano-therapy, oxygen therapy, ozone therapy, artificial respiration and aerosol therapy appliances, massage apparatus, etc., of heading 9019; (n) orthopaedic appliances, artificial parts of the body and fracture appliances, including such appliances for animals (heading 9021); (o) X-ray apparatus, etc. (whether or not for medical use) of heading 9022; (p) clinical thermometers (heading 9025); (q) instruments and apparatus used in laboratories for the analysis of blood, tissue fluids, urine, etc., whether or not these analyses serve diagnostic purposes (generally heading 9027);

(r) medical or surgical furniture, including furniture for veterinary use (operating tables, examination tables, hospital beds), dentists' chairs not incorporating dental appliances of this heading, etc. (heading 9402). However, this heading covers specialised measuring instruments used exclusively in professional practice, such as cephalometers, measuring callipers for measuring cerebral lesions, obstetric pelvimeters, etc. It should also be noted that many of the instruments used in medicine or surgery (human or veterinary) are essentially ordinary hand tools (e.g., hammers, dental mallets, saws, chisels, gouges, forceps, pincers, spatulas, etc.) or cutlery (scissors, knives, etc.). Such articles are therefore classified in this heading only if they are clearly identifiable as intended for medical or surgical use by reason of their special shape, the ease with which they can be dismantled for sterilisation, their superior quality of manufacture, the nature of their constituent metals or the way they are put up (often in cases or boxes containing a set of instruments for a particular operation: obstetrics, autopsies, gynaecology, eye or ear surgery, veterinary obstetric sets, etc.). The instruments and appliances classified here may be fitted with optical devices; they may also use electricity, either as motive power, or for transmission, or as a prophylactic, therapeutic or diagnostic agent. This heading also covers instruments and appliances using laser or other light or photon beam processes, and ultrasonic instruments and appliances. (I) INSTRUMENTS AND APPLIANCES FOR MEDICINE OR SURGERY This category covers: (A) Instruments which may be used under the same name for several purposes, for example: (1) Needles (suture, ligature, vaccination, blood-test, hypodermic, etc.). (2) Lancets (vaccination, blood-letting, etc.). (3) Trocars (for punctures) (gall bladder, general purpose, etc.). (4) Surgical knives and scalpels of all kinds. (5) Probes (prostate, bladder, urethral, etc.). (6) Dilators (nasal, oral, laryngeal, rectal, vaginal, etc.). (7) Mirrors and reflectors (eye, laryngeal, ear, etc.). (8) Scissors, forceps, pincers, chisels, gouges, neurologists' hammers, dental mallets, saws, scrapers, spatulas. (9) Hollow needles, catheters, aspiration tubes, etc. (10) Cauteries (thermo-cauteries, galvano-cauteries, micro-cauteries, etc.). (11) Tweezers; holders for dressings, swabs, sponges or needles (including radium needle holders). (12) Retractors (lip, jaw, abdominal hooks, tonsil hooks, liver retractors, etc.).

(13) Dilators (for the larynx, urethra, esophagus, dilators of the cervical canal, etc.). (14) Wire guides used to insert catheters, needles, tissue expanders, endoscopes and atherectomic devices. (15) Brackets (for stitches, etc.). (16) Syringes (glass, metal, glass and metal, plastics, etc.) of all kinds, for example, injection, puncture, for anesthesia, douching, wound washing, aspiration (with or without a pump), for eyes, ears, throat, uterine, gynecological, etc. (17) Surgical staplers for braces installation to close the wound. (B) Special diagnostic devices and apparatus. These include: (1) Stethoscopes. (2) Instruments for measuring respiratory rate (to determine the basic exchange). (3) Sphygmomanometers, tonometers and oscillo meters (to measure blood pressure). (4) Spirometers (to determine lung volume). (5) Cephalometers. (6) Tasometers. (C) Instruments for the study of vision. They fall into different categories: (1) Surgical instruments, such as corneal trefins, keratomas. (2) Diagnostic devices such as ophthalmoscopes; binocular magnifiers with headbands and binocular-type microscopes consisting of a microscope, an electric lamp with a slit and a head restraint, all generally mounted on an adjustable support for eye examination; tonometers (to check intraocular pressure); detachers. (3) Vision correction devices or visual examination devices, including amblyoscopes, retinoscopes, sciascopes, strabometers, keratometers, keratoscopes, eye meters designed to measure the distance between the pupils, boxes with test lenses and test frames (for wearing test lenses), optometric scales, test tables. However, optometric scales and tables on paper, cardboard or plastic used for checking and perceiving colour are not included in this heading (Chapter 49). This heading also includes electrically heated eye compresses and electromagnets designed to remove metal particles from the eye. (D) Ear instruments, such as oriscopes. However, tuning forks, whether or not intended for medical use, are not included in this heading (heading 9209). (E) Anesthetic devices and tools (face masks, devices for partial processing of the face, intubation tubes, etc.). (F) Tools for treating the nose, throat or amygdala: clamps (for straightening the nasal cartilage); transillumination devices (for sinuses and nasal glands)

sinuses and nasal fossae); tonsillotomes and surgical instruments for removing tonsils; direct laryngoscopes; laryngeal brushes, etc. (G) Pharyngeal, oesophageal, gastric or tracheotomy instruments: oesophagoscopes, bronchoscopes, apparatus for aspirating the gastric contents, intubation tubes, etc. (H) Instruments for the urethra or bladder: urethrotomes, apparatus for aspirating bladder stones, instruments for prostatectomy and for crushing stones. (IJ) Artificial kidney (dialysis) apparatus. (K) Gynaecological or obstetrical instruments: vaginal retractors; instruments for extirpation of the uterus; obstetrical stethoscopes; specialised optical instruments for examining the genital organs; forceps; perforators; embryotomy instruments (for dismembering the foetus); cephalotribes and cranioclasts (instruments for crushing the head of a child that has died in the womb); instruments for taking internal measurements, etc. (L) Portable pneumothorax apparatus; transfusion apparatus for whole blood, blood components and blood derivatives; artificial leeches. This heading also covers sterile sealed plastic containers from which the air has been removed but which contain a small quantity of anticoagulant and are fitted with an integral donor tube and phlebotomy needle, used for the collection, storage and transfusion of human whole blood. However, special glass bottles for storing blood are excluded (heading 7010). (M) Electric devices for grinding down corns on the feet. (N) Acupuncture needles: gold, silver, steel. (O) Endoscopes: gastroscopes, thoracoscopes, peritoneoscopes, bronchoscopic telescopes, cystoscopes, urethroscopes, resectoscopes, cardioscopes, colonoscopes, nephroscopes, laryngoscopes, etc. Many of these have an operating channel large enough for surgery to be carried out by means of remotely controlled instruments. However, endoscopes for non-medical purposes (fibrescopes) are excluded (heading 9013). (P) Apparatus incorporating a computer and designed solely for calculating the dose and distribution of therapeutic radiation. (Q) Hyperbaric chambers (also known as decompression chambers), which are specially equipped pressure chambers for administering oxygen at a pressure above atmospheric pressure. They are used for treating conditions such as decompression sickness, air embolism, gas gangrene, carbon monoxide poisoning, refractory osteomyelitis, skin grafts, actinomycosis and particular cases of anaemia due to blood loss. (R) Lamps specially designed for diagnostic, probing, irradiation, etc., purposes. Torches, e.g., of the fountain-pen type, are excluded (heading 8513), as are other lamps not clearly identifiable as intended for medical or surgical purposes (heading 9405).

(II) DENTAL INSTRUMENTS AND APPLIANCES In addition to the instruments and appliances common to this and the preceding category (such as masks and other dental analgesic apparatus), the principal instruments and appliances in this category are: (1) Surgeons' finger guards (whether or not joined together) and mouth gags; cheek and lip retractors; tongue depressors and clamps. (2) Tweezers of all kinds, elevators, forceps of all kinds (for extracting teeth, for straightening teeth, etc.), dental cutters (for dissecting, ligaturing, filling and excavating, etc.), root forceps. (3) Endodontic instruments (nerve extractors, drill broaches, dental files, filling instruments, reamers, etc.). (4) Bone nippers and dilators; gouges and dental mallets for resection of the jaw and of the maxillary sinus; raspatories; scalpels; special knives and scissors; special dentists' tweezers; "excavators" and probes. (5) Special instruments for cleaning the gums and sockets; scaling instruments for removing tartar; scrapers and chisels for dental enamel. (6) Various probes; needles (abscess, hypodermic, suture, cotton-wool, etc.); holders for cotton-wool pads and swab sticks; insufflators; dental mirrors. (7) Gold-packing instruments (pluggers, dental mallets, etc.); filling instruments (spatulas for cement or resin, plugs and dental mallets for amalgam, instruments for inserting amalgam into the tooth cavity, etc.); impression trays. (8) Dental burs, discs, dental drills and brushes, specially designed for use with the dental engine or drill handpiece. This heading also covers instruments used in prosthetic dentistry both by the practitioner himself and by the dental technician, for example: knives; spatulas and other modelling instruments; various pliers and tweezers (for fixing clasps and crowns, trimming projections, etc.); saws; scissors; dental mallets; reamers; chisels; scrapers; finishing burs; metal-forming devices for producing metal dental crowns by striking. This heading also includes dental casting machines, dental milling machines and trimming machines for models of dental prostheses. This heading does not, however, cover tools or other articles of general use (furnaces, moulds, soldering irons, melting ladles, etc.); these fall in their appropriate headings. This heading also covers the following: (i) dental drill engines with a swivelling tool-holder arm, on a separate base designed for mounting on the wall or on the equipment described in item (ii) below;

(ii) complete dental equipment on its own base (stationary or mobile unit). The main usual components are a frame carrying a compressor, a transformer, a control panel and other electrical apparatus; the unit is often also fitted with the following: a dental drill with a swivelling tool-holder arm, a spittoon and mouth-rinsing device, an electric heater, hot-air insufflators, a sprayer, a tray of cauterising instruments, diffused lighting, a shadowless lamp, a fan, diathermy apparatus, X-ray apparatus, etc. Some types of this equipment are designed to work with abrasive materials (usually aluminium oxide) instead of a bur; the abrasives are usually applied to the teeth by a compressed gas (e.g., carbon dioxide); (iii) spittoons and mouth-rinsing bowls, on a base, on a pedestal or on a swivel. They are usually combined with a warm-water supply and a warm-water syringe; (iv) polymerisation units (light or heat curing), amalgamators, ultrasonic scaling units, electro-surgical equipment, etc.; (v) laser-operated dental treatment units; (vi) dentists' chairs incorporating dental equipment or any other dental appliances covered by this heading. This heading does not, however, cover dentists' chairs not incorporating dental appliances of this heading; such dentists' chairs fall in heading 9402 whether or not they are fitted with equipment such as lights. It should be noted, however, that certain items of the dental equipment mentioned in item (ii) above are excluded from this heading when presented separately; they fall in their appropriate headings, e.g., compressors (heading 8414); X-ray and other apparatus (heading 9022). Heading 9022 also covers X-ray and other apparatus designed for separate installation or for mounting on the wall in dental surgeries. Diathermy apparatus presented separately, however, is classified with the electro-medical apparatus of this heading (see item (IV) below). It should be noted that dental cements and other dental fillings fall in heading 3006; preparations known as "dental wax" or "dental impression compounds", put up in sets, in packings for retail sale or in plates, horseshoe shapes, sticks or similar forms, and other preparations for use in dentistry with a basis of plaster (of calcined gypsum or calcium sulphate) fall in heading 3407. (III) VETERINARY INSTRUMENTS AND APPLIANCES This category covers a large number of articles which, although intended for veterinary use, are similar to those listed in item (I) or (II) above, for example: (A) General-purpose instruments (e.g., needles, lancets, trocars, scalpels, mirrors, probes, scissors, forceps, hammers, curettes, retractors, syringes). (B) Special instruments and appliances, such as ophthalmoscopes, eyelid retractors, laryngoscopes, stethoscopes, forceps, embryotomes. (C) Dental instruments. This category also covers instruments and appliances specially designed for veterinary use, for example:

(1) Tools and devices for udders, for example, dealers for breast nipples and puncture probes (to open the nipples of cows); devices for the treatment of postpartum sepsis or mastitis in cows. (2) Tools and devices for castration: tools for crushing the sperm cord; gluing and clamps for castration (in order to cause atrophy of the sex glands in males); clutches and forceps for castration; ovariotomas, etc. (3) Tools and devices for childbirth: specialized obstetric ropes, tethered belts, devices for fixing the head, forceps and hooks, mechanical devices for calves, etc. (4) Various tools: artificial insemination devices; devices for fixing the tail; devices for cutting the horns; sprayers for treating diseases of the respiratory, digestive, urethra, genital, etc. organs in animals; special control devices, that is, to prevent the movements of animals during operations (rotor expanders, knots, etc.); special syringes for the introduction of drugs and syringes filled with an anesthetic preparation or medicine (immune serum, vaccine, etc.) for remote insertion with a shotgunator; special tools for fixing a spear at the floor with a spear, for the help of a pist, for a spear, for a spearhead, for a spearhead, for example, for the use of a honking a pist, for a honk, for a spike, for a spike at a spear, for a spike, for a spike at a spearhead, for a spike, for a spike, or for a rod, for example, for a rod, for a rod, for example, for a honking a This heading does not include triquinoscopes (optical devices for the examination of pork) (heading 9011), orthopedic devices for animals (heading 9021), operating tables for animals (heading 9402, see the relevant explanations). Tools used equally by veterinary surgeons and blacksmiths are classified in Chapter 82 (e.g. front hoof filers; scissors for but veins or hooves; knives for cutting; mites; tweezers; hammers, etc.); Chapter 82 also includes tools for branding cattle (stamps, irons for annealing hooves, etc.) and cutting tools. (IV) SCINTIGRAPHIC AGREEMENTS are devices that scan parts of the body and create images of an organ or record its work. This category includes equipment equipped with a scintillation counter, the data of which are converted into analog signals for the purpose of making medical diagnoses (for example, a gamma camera, a scintillation scanner). This heading also includes electromedical apparatus for prophylactic, curative or diagnostic purposes other than X-ray, etc. apparatus of heading 9022. This category of products includes: (1) electrodiagnostic equipment, which includes: (i) electrocardiographs (devices that, using currents caused by contractions of the heart muscle, record the movements of the heart in the form of electrocardiograms); (ii) phonocardiographs (specially designed to record cardiac noise in the form of phonocardiograms; they can also be used as electrocardiographs); (iii) cardioscopes (used in combination with the two previous devices for simultaneous observation of cardiograms and phonocardiograms);

(iv) rheocardiographs (electrical apparatus for measuring the changes in electrical resistance caused by the functioning of the heart); (v) electro-encephalographs (for examining the brain); (vi) electro-sphygmographs (for recording arterial pressure and volume); (vii) electro-tonographs (for recording variations in arterial, intravenous or intracardiac pressure); (viii) electro-retinographs (for measuring the voltage in the retina); (ix) audiometers and similar apparatus (for testing hearing on the basis of frequency variation); (x) diagnostic apparatus combined with, or working in conjunction with, a computer, for processing and displaying clinical data, etc.; (xi) ultrasonic diagnostic equipment used for imaging organs (e.g., on a display) by means of ultrasonic waves; (xii) nuclear magnetic resonance (NMR) apparatus, used for presenting the characteristics of the tissues and internal organs of the human body by using the magnetic properties of the body's atoms, such as hydrogen atoms. (2) Electro-therapy apparatus. Besides its diagnostic use, this apparatus is used for treating diseases such as neuritis, neuralgia, hemiplegia, phlebitis, endocrine anaemia. Some of these appliances may be combined with the electro-surgical instruments referred to in item (7) below. (3) Ionotherapy apparatus used for introducing active medicaments (sodium or lithium salicylate, potassium iodide, histamine, etc.) through the skin by means of an electric current. (4) Diathermy apparatus for treating certain diseases requiring heat (e.g., rheumatism, neuralgia, dental diseases). It operates by means of high-frequency (short-wave, ultrasonic, ultra-short-wave, etc.) currents and uses electrodes of various shapes (e.g., plates, rings, tubes). (5) Electro-shock apparatus for treating mental or nervous disorders. (6) Cardiac defibrillators for restoring the heart rhythm, operating by means of an electric current. (7) Electro-surgical apparatus. This uses high-frequency electric currents, a needle, probe, etc., forming one of the electrodes. It may be used for cutting tissue (electrotomy) by means of a lancet (electric lancet) or for coagulating blood (electro-coagulation). Certain combined instruments can, by means of control pedals, be made to act alternately as electric cutters or electro-coagulators. (8) Actinotherapy apparatus. This uses radiations lying within, but more often outside, the visible spectrum (infra-red, ultra-violet) for treating certain diseases or for diagnostic purposes (special lighting for detecting skin diseases). This apparatus usually incorporates lamps, although infra-red apparatus may be fitted with heating resistors or heated panels with reflectors.

(9) Incubators for babies. These consist essentially of a transparent plastic compartment, electrical heating equipment, safety and alarm devices and apparatus for air filtration, oxygen supply and regulation. In most cases they are mounted on a trolley and incorporate baby scales. Housings containing electrodes or other devices intended for use with the apparatus described above also fall in this category. This heading also excludes prenatal listening apparatus for non-medical use of heading 8518 (see the Explanatory Note to that heading). PARTS AND ACCESSORIES Subject to the provisions of Notes 1 and 2 to this Chapter (see the General Explanatory Note), parts and accessories of apparatus or appliances of this heading are also classified in this heading. Subheading Explanatory Notes. Subheading 9018 12 This subheading covers ultrasonic scanning electro-diagnostic apparatus. This apparatus operates by using high-frequency sound waves emitted into the human body through a transducer. The transducer is placed in direct contact with the body and alternately emits short pulses of ultrasound and "listens" for their echoes; the characteristics are interpreted to obtain information on the location, size, shape and structure of tissues. Interpretation is usually carried out by a computer with an output device displaying a video image of the organs. This method of body scanning is used for examining the foetus in pregnant women. It is also frequently used for examining the breast, heart, liver and gall bladder. Subheading 9018 13 Magnetic resonance imaging is based on the principle of alignment of the nuclei of hydrogen atoms in strong magnetic fields. If a high-frequency signal is then directed at these atoms, their alignment is disturbed. When the radio waves are switched off, the atoms realign, emitting a weak electrical signal in the process of realignment. Since the human body consists largely of hydrogen atoms, an image of virtually any region of the body can be obtained by means of the returned pulses. Since hydrogen is a constituent of water, the returned pulses can be used to distinguish between tissues. This makes it possible to obtain images of bone marrow and soft tissues. The magnetic resonance imaging electro-diagnostic apparatus of this subheading consists of a giant electromagnet, a high-frequency generator and a computer for processing. It must be installed in a room completely shielded from external electromagnetic fields. To obtain a highly efficient magnetic field of the required strength, electromagnets cooled to extremely low temperatures by liquid helium are necessary. Hydrogen was chosen as the basis for magnetic resonance imaging because of its abundance in the human body and its known magnetic characteristics. The use of other elements, such as sodium or phosphorus, is also possible. Subheading 9018 14

The electro-diagnostic apparatus of this subheading is used to obtain an image by irradiating the human body with gamma rays. This image is produced by appropriate apparatus, such as a scintigraphic scanner and, best of all, a gamma camera. These nuclear scanners require the patient to be given, orally or by injection, a radioactive compound (tracer) which is rapidly absorbed by the organ under study. The body is then scanned by a gamma counter which records the amount of radiation emitted by the tracer that has penetrated the organ in question (e.g., the brain), in order to determine where the isotope has been absorbed. A video image is produced by computer analysis of the recorded radiation. This image consists of a set of light and dark areas or contrasting coloured spots and shows where in the organ the radioisotope has been absorbed. Such scanning makes it possible to obtain information on the structure and function of the organ being examined. An example of scintigraphic apparatus is the positron emission tomograph (PET). It combines the principle of nuclear medicine with the technology used in computed tomography (see the Explanatory Note to subheading 9022 12).

Official text adopted by a Recommendation of the EEC Board

Notes to chapter 90 — Optical, photographic, cinematographic, measuring, checking, precision, medical or surgical instruments and apparatus; parts and accessories thereof 8 items

Notes

Machine translation. The original is the Russian text of the EAEU tariff, and customs goes by it; this translation is for understanding only and has no legal force.

1. This group does not include:

(a) articles used in machinery, appliances or for other technical purposes, made of vulcanised rubber other than hard rubber (heading 4016), natural or composite leather (heading 4205) or textile material (heading 5911);

(b) support belts or other supporting articles of textile materials, the purposeful effect of which on the supported or fixed organ is only due to their elasticity (for example, bandages for pregnant women, chest bandages, abdominal bandages, joint or muscle locks) (Section XI);

(c) refractory articles of heading 6903; ceramic articles for laboratory, chemical or other technical purposes of heading 6909;

(d) optically raw glass mirrors of heading 7009 or of base or precious metal mirrors other than optical elements (heading 8306 or Chapter 71);

(e) the goods of heading 7007, 7008, 7011, 7014, 7015 or 7017;

(f) parts of general use referred to in Note 2 to Section XV of base metals (Section XV) or similar products of plastics (Chapter 39); however, articles specifically intended for use exclusively in implants used in medicine, surgery, dentistry or veterinary medicine are to be classified in heading 9021;

(ж) насосы с измерительными приборами товарной позиции 8413; счетное или контрольное оборудование, приводимое в действие силой тяжести взвешиваемого груза, или поставляемые отдельно разновесы для весов (товарная позиция 8423); подъемное или погрузочно-разгрузочное оборудование (товарные позиции 8425 – 8428); машины всех видов для резки бумаги или картона (товарная позиция 8441); приспособления для регулирования положения обрабатываемых деталей или инструмента на станках или водоструйных резательных машинах товарной позиции 8466, включая приспособления с оптическими элементами для считывания показаний приборов (например, «оптические» делительные головки), но за исключением тех устройств, которые сами по себе являются исключительно оптическими приборами (например, юстировочные телескопы); счетные машины (товарная позиция 8470); клапаны и другая арматура товарной позиции 8481; машины и аппаратура (включая аппаратуру для проецирования или нанесения рисунка маски на сенсибилизированные полупроводниковые материалы) товарной позиции 8486;

(з) прожекторы или фары, используемые на велосипедах или моторных транспортных средствах (товарная позиция 8512); портативные электрические фонари товарной позиции 8513; кинематографические аппараты для записи, воспроизведения или повторной записи звука (товарная позиция 8519); звуковые головки (товарная позиция 8522); телевизионные камеры, цифровые камеры и записывающие видеокамеры (товарная позиция 8525); радиолокационная аппаратура, радионавигационная аппаратура или радиоаппаратура дистанционного управления (товарная позиция 8526); соединители для волокон оптических, волоконно-оптических жгутов или кабелей (товарная позиция 8536); цифровые аппараты управления товарной позиции 8537; лампы герметичные направленного света товарной позиции 8539; волоконно-оптические кабели товарной позиции 8544;

(ij) floodlights or headlights of heading 9405;

(k) articles of Chapter 95;

(l) monopores, bipeds, tripods and similar articles of heading 9620;

(m) volume measuring tanks classified by the material from which they are made; or

(n) coils, reels or similar carriers (which are to be classified according to the material of which they are made, for example, in heading 3923 or in section XV).

2. Subject to the provisions of Note 1, parts and accessories to machinery, apparatus, tools or articles in this Chapter shall be classified according to the following rules:

(a) parts and accessories which are goods falling in one of the headings of this Chapter or of Chapter 84, 85 or 91 (other than heading 8487, 8548 or 9033) are in all cases classified in the relevant headings;

(b) other parts and accessories intended to be used exclusively or principally in a particular type of machine, tool or apparatus or in several machines, tools or apparatus falling under the same heading (including machinery, tools or apparatus of heading 9010, 9013 or 9031) are included with those machines, tools or apparatus;

(c) all other parts and accessories fall in heading 9033.

3. Notes 3 and 4 to section XVI also apply to this chapter.

4. Heading 9005 does not include telescopic sights for mounting weapons, telescopic periscopes for submarines or tanks, or sight-tubes fitted to machines, devices, instruments or apparatus of this Chapter or Section XVI; such telescopic sights and sight-tubes are classified in heading 9013.

5. Measuring or control optical devices, devices or machines which, but for this note, could be included in both heading 9013 and heading 9031 are classified in heading 9031.

6. For the purposes of heading 9021, the term “orthopedic devices” means devices for:

prevention or correction of bodily deformities; or

Supporting or fixing body parts after illness, surgery, or injury.

Orthopedic appliances include shoes and special insoles made for the correction of orthopedic conditions, provided that they are either (1) made to order standards, or (2) mass-produced, represented by one object and not in pairs and designed to be equally suitable for any foot.

7. Heading 9032 covers only:

(a) instruments and devices for the automatic control of the flow rate, level, pressure or other variable parameters of liquids or gases, or for the automatic control of temperature, whether or not their action is based on an electrical phenomenon varying according to the parameter to be regulated, which are designed to bring this parameter to the desired value and to keep it stable against disturbances, constantly or periodically measuring the actual value; and

(b) automatic regulators of electrical quantities and devices or devices for the automatic regulation of non-electrical quantities, the operation of which is based on an electrical phenomenon varying depending on the parameter to be regulated, which are designed to bring this parameter to the desired value and keep it stable from disturbances, constantly or periodically measuring the actual value.

Additional note

Machine translation. The original is the Russian text of the EAEU tariff, and customs goes by it; this translation is for understanding only and has no legal force.

1. Термин «электронные» в подсубпозициях 9015 10 100 0, 9015 20 100 0, 9015 30 100 0, 9015 40 100 0, 9015 80 110 0, 9015 80 190 0, 9024 10 110 0, 9024 10 130 0, 9024 10 190 0, 9024 80 110 0, 9024 80 190 0, 9025 19 200 0, 9025 80 400 0, 9026 10 210 0, 9026 10 290 0, 9026 20 200 0, 9026 80 200 0, 9027 10 100 0, 9030 20 910 0, 9030 33 100 0, 9030 89 300 0, 9031 80 320 0, 9031 80 340 0, 9031 80 380 0 и 9032 10 200 0 означает приборы и аппараты, которые включают в себя одно или несколько изделий товарной позиции 8540, 8541 или 8542. Однако это не должно относиться к изделиям товарной позиции 8540, 8541 или 8542, функцией которых является исключительно выпрямление тока или которые входят в состав блока питания приборов или аппаратов.

EEC classification decisions (3)

Binding in all EAEU member states: if the goods match the description, the decision fixes the code

Classification rulings for this code (16)

Machine translation from Russian. The original is the Russian wording of the ruling, and customs goes by it; this translation is for understanding only and has no legal force.

The product is a T-shaped intrauterine therapeutic system with the content of the active ingredient levonorgestrel micronized 52 mg (CAS No. 797-63-7), which, after introduction into the uterus, releases the hormone levonorgestrel directly into the uterine cavity.

Full description

The intrauterine system consists of a hormone-elastomeric core placed on a T-shaped body and covered with an opaque membrane that regulates the release of levonorgestrel (20 μg / 24 hours). The T-shaped body is equipped with a loop at one end and two shoulders at the other, threads are attached to the loop to remove the system. The intrauterine system is placed in the conductor tube (the components of the conductor are the insertion tube, the piston, the index ring, the handle and the runner). It is used to prevent pregnancy (contraception), treat idiopathic menorrhagia and prevent endometrial hyperplasia during hormone replacement therapy with estrogen.

It is supplied in a blister with a leaf insert (pamphlet for the patient and instructions for the doctor for the introduction of the IUD) and a memo for the user in a cardboard pack.

GRI 1 and 6

A set of manual surgical orthopedic instruments made of stainless steel is used in professional practice by surgeons to perform surgical operations for the reconstruction of the cervical vertebrae (C3-C7) in the treatment of diseases of the cervical spine (cervical osteochondrosis, intervertebral hernia and kyphotic deformity of the cervical region) by implantation of the endoprosthesis (not included in the kit).

Full description

The kit tools are placed in a stainless steel container, stacked in special individual staff places and fixed at the expense of the container lotions. The container is closed with two opposite metal valves. The kit consists of the following tools: holder of the Caspar detector pin; cutter tool for the introduction of a dynamic endoprosthesis of the cervical intervertebral disc; gripper; cage insertion tool; fitting spacer (test dynamic endoprosthesis) 17x14x 6.5 mm; fitting spacer (test dynamic endoprosthesis) 15x12x5.5 mm; fitting spacer (test dynamic endoprosthesis) 15x12x7.5 mm; fitting spacer (test dynamic endoprosthesis) 17x14x5.5 mm; fitting spacer (test dynamic endoprosthesis) 17x14x7.5 mm;

Distractor Caspar; The detector pin; tool container composed: container 1 piece, container cover (located in a normal place inside the main container and designed for the location of implants (not included in the kit)); tool container composed: 1st container, Container cover (designed to accommodate a set of tools and a container for implants). During the operation, the surgeon chooses the sequence of application of all tools of the set. The container with a set of tools is supplied in non-sterile form, packed in a cardboard box with a label containing information about the name of the goods, article number, manufacturer.

GRI 3(b) and 6

The patient's tube is a disposable sterile product for medical use in the form of a tube of polyvinyl chloride 320 cm long.

Full description

The product consists of the following components: the tube, the nesting part of the Luer connector, protective caps for the ends of the tube, the plug part of the Luer connector with a return valve, the second return valve. The patient's tube is an affiliation of a medical device - an automatic angiographic injector for computed tomography and is used as a connecting highway between the patient's cannula and the pump tube to deliver contrast material and physiological solution to the patient's body. It is connected using standard Luer-lock connectors.

GRI 1 and 6

The patient's tube is a disposable sterile product for medical use in the form of a tube of polyvinyl chloride with a length of 250 cm.

Full description

The product consists of the following components: the tube, the nesting part of the Luer connector, protective caps for the ends of the tube, the plug part of the Luer connector with a return valve, the second return valve. The patient's tube is an affiliation of a medical device - an automatic angiographic injector for computed tomography and is used as a connecting highway between the patient's cannula and the pump tube to deliver contrast material and physiological solution to the patient's body. It is connected using standard Luer-lock connectors.

GRI 1 and 6

Consumable, sterile, plastic, disposable product is used in conjunction with arthroscopic pump (not included in the delivery) during arthroscopic operations on the joints to ensure the flow of irrigation fluid to the knee, shoulder, hip and small joints, in order to perform uniform expansion and visualization of the surgical area.

Full description

The product consists of the following main elements: a transparent tube (provides the supply of liquid from the irrigation bag / bags to the cassette). On one side, the tube has a Y-shaped branching with clamps and plastic needle-like tips to connect two irrigation bags. The other side of the tube connects to the cassette; blue tube (provides the supply of irrigation fluid from the cassette to the joint cavity). On one side, the tube connects to the cassette. The other side of the tube is equipped with a clamping, and through a cannula (not included in the delivery) is brought into the joint cavity; the cassette in the form of a plastic rectangular box connected to a transparent and blue tubes has a mechanism for supplying fluid in the form of an impeller rotating by means of a magnetic drive from the pump, a fluid flow pressure sensor and a system of fastenings for fixation in the pump.

Principle of operation: the cassette is fixed in the pump. A transparent tube is connected to an irrigation bag/package with liquid. The blue tube is connected to the supply cannula, which is inserted into the joint cavity. The pump is activated, which drives the impeller inside the cassette, which ensures the translational movement of fluid from the irrigation bag / bags into the joint cavity. The length of each tube is 304.8 cm. The diameter of each tube is 8.89 mm. The size of the cassette (DhVhSh) 115×88.6×30.2 mm.

The product comes in individual sterile packaging of three pieces in a cardboard box.

GRI 1 and 6

The connecting line for the patient (hereinafter referred to as the Patient Line) is a disposable sterile product for medical use in the form of a 150 cm long polyvinyl chloride tube, the ends of which are provided with Luer-lock connectors.

Full description

The patient's line is an affiliation to medical devices - automatic injectors and is designed to supply liquids of contrast agent and physiological solution (NaCl) into the patient's body during computed tomography, magnetic resonance imaging and X-ray mammography. The patient's line connects the patient's catheter (not included in the delivery) with the hose system (not included in the delivery), attached to the syringe flask installed in the automatic injector, or directly to the syringe flask (not included in the delivery).

GRI 1 and 6

Consumable, sterile, plastic, disposable product is used by orthopedic traumatologists in conjunction with arthroscopic pump (not included in the delivery) during arthroscopic operations on the joints for the inflow / outflow of irrigation fluid into the knee, shoulder, hip and small joints, in order to maintain intraarticular pressure to perform uniform expansion and visualization of the surgical area.

Full description

The product consists of the following main elements: a transparent tube with a length of 2590 mm (provides the supply of liquid from the irrigation bag / bags to the cassette). On one side, the tube has a Y-shaped branching with clamps and plastic needle-like tips to connect two irrigation bags. The other side of the tube connects to the cassette; a blue tube 3048 mm long (provides the supply of irrigation fluid from the cassette to the joint cavity). On one side, the tube connects to the cassette. The other side of the tube is equipped with a clamp, and by means of a cannula (not included in the delivery) is brought into the joint cavity; a diversion transparent tube 3240 mm long (for the outflow of fluid from the joint cavity).

On one side, the tube has a Y-shaped branching to attach to two surgical instruments. The tube moves away from the surgical instruments, passes through the casing of the cassette into the waste container. The outflow of liquid is carried out by gravity, or with the help of a surgical aspirator for suction (not included in the delivery); a cassette in the form of a plastic rectangular box connected to a transparent and blue tube, also through it passes a draining transparent tube, has a mechanism for supplying fluid in the form of an impeller rotating by means of a magnetic drive from the pump, a fluid flow pressure sensor and a system of fastenings for fixation in the pump.

Principle of operation: the cassette is fixed in the pump. A transparent tube is connected to an irrigation bag/package with liquid. The blue tube is connected to the lead cannula, which is inserted into the joint cavity. A transparent tube is attached to two surgical instruments. The pump is activated, which drives the impeller inside the cassette, which ensures the translational movement of fluid from the irrigation bag / bags into the joint cavity. The outflow of liquid is carried out through a transparent tube.

The outer diameter of each tube is 8.89 mm. The size of the cassette (DhVhSh) 115×88.6×30.2 mm. The product comes in individual sterile packaging of three pieces in a cardboard box.

GRI 1 and 6

Consumable, sterile, plastic, disposable product is used by orthopedic traumatologists in conjunction with arthroscopic pump (not included in the delivery) during arthroscopic operations on the joints for the inflow / outflow of irrigation fluid into the knee, shoulder, hip and small joints, in order to maintain intraarticular pressure to perform uniform expansion and visualization of the surgical area.

Full description

The product consists of the following main elements: a transparent tube with a length of 2590 mm (provides the supply of liquid from the irrigation bag / bags to the cassette). On one side, the tube has a Y-shaped branching with clamps and plastic needle-like tips to connect two irrigation bags. The other side of the tube connects to the cassette; a blue tube 3048 mm long (provides the supply of irrigation fluid from the cassette to the joint cavity). On one side, the tube connects to the cassette. The other side of the tube is equipped with a clamp, and by means of a cannula (not included in the delivery) is brought into the joint cavity; a diversion transparent tube 3240 mm long (for the outflow of fluid from the joint cavity).

The tube moves away from the surgical instrument, passes through the casing of the cassette into the waste container. The outflow of liquid is carried out by gravity, or with the help of a surgical aspirator for suction (not included in the delivery); a cassette in the form of a plastic rectangular box connected to a transparent and blue tube, also through it passes a draining transparent tube, has a mechanism for supplying fluid in the form of an impeller rotating by means of a magnetic drive from the pump, a fluid flow pressure sensor and a system of fastenings for fixation in the pump.

Principle of operation: the cassette is fixed in the pump. A transparent tube is connected to an irrigation bag/package with liquid. The blue tube is connected to the supply cannula, which is inserted into the joint cavity. A transparent tube is attached to the surgical instrument. The pump is activated, which drives the impeller inside the cassette, which ensures the translational movement of fluid from the irrigation bag / bags into the joint cavity. The outflow of liquid is carried out through a transparent tube.

The outer diameter of each tube is 8.89 mm. The size of the cassette (DhVhSh) 115×88.6×30.2 mm. The product comes in individual sterile packaging of three pieces in a cardboard box.

GRI 1 and 6

The consumable, sterile, plastic, disposable product is used by orthopedic traumatologists in conjunction with the GoFlo arthroscopic pump (not included in the delivery) during arthroscopic operations on the joints to ensure the flow of irrigation fluid to the knee, shoulder, hip and small joints, in order to maintain intraarticular pressure to perform uniform expansion and visualization of the surgical area.

Full description

The product is a transparent tube with a length of 476 cm, an external diameter of 9.89 mm. On one side, the tube has a Y-shaped branching with clamps and needle-like tips to connect two irrigation bags. The other side of the tube has a clamp and a luer connector to connect to the arthroscope (not included in the delivery). The tube is integrated with a device measuring 25 mm x 27 mm x 28 mm, containing a sensor that recognizes the type of tubes, the fitness and reliability of a set of tubes (transponder) and a membrane combined with the injection chamber, measuring the pressure of the solution passing through the tube.

Principle of operation: the injection chamber tube is installed in the clip for the tubes of the arthroscopic pump. One side of the tube is connected to the irrigation bag/liquid packets. On the opposite side, the tube connects to the arthroscope, through which the fluid enters the joint cavity. A pump is activated, the roller mechanism of which sequentially compresses the elastic tube with rollers rotating around the circle, which ensures the translational movement of fluid from the irrigation bag / packages into the joint cavity.

The product is not suitable for cleaning and re-sterilization. The product comes in a cardboard box in the amount of 10 pieces in the package. The packaging is sterile.

GRI 1 and 6

Non-sterile, plastic, for repeated use (up to 20 cycles of use), the product is used by orthopedic traumatologists in conjunction with the arthroscopic pump GoFlo (not included in the package) during arthroscopic operations on the joints to ensure the flow of irrigation fluid to the knee, shoulder, hip and small joints, in order to maintain intra-articular pressure to perform uniform expansion and visualization of the surgical area.

Full description

The product is a transparent tube with a length of 476 cm, an external diameter of 9.89 mm. On one side, the tube has a Y-shaped branching with clamps and needle-like tips to connect two irrigation bags. The other side of the tube has a clamp and a luer connector to connect to the arthroscope (not included in the delivery). The tube is integrated with a device measuring 25 mm x 27 mm x 28 mm, containing a sensor that counts the amount of use of the tube (transponder) and a membrane combined with the injection chamber, measuring the pressure of the solution passing through the tube.

Principle of operation: the injection chamber tube is installed in the clip for the tubes of the arthroscopic pump. One side of the tube is connected to the irrigation bag/liquid packets. On the opposite side, the tube connects to the arthroscope, through which the fluid enters the joint cavity. A pump is activated, the roller mechanism of which sequentially compresses the elastic tube with rollers rotating around the circle, which ensures the translational movement of fluid from the irrigation bag / packages into the joint cavity.

The product comes in a cardboard box in the amount of 10 pieces in the package.

GRI 1 and 6

Consumable, sterile, plastic, disposable product is used by orthopedic traumatologists in conjunction with arthroscopic pump (not included in the delivery) during arthroscopic operations on the joints to ensure the flow of irrigation fluid to the knee, shoulder, hip and small joints, in order to maintain intraarticular pressure to perform uniform expansion and visualization of the surgical area.

Full description

The product consists of the following main elements: a transparent tube with a length of 2590 mm (provides the supply of liquid from the irrigation bag / bags to the cassette). On one side, the tube has a Y-shaped branching with clamps and plastic needle-like tips to connect two irrigation bags. On the other side, the tube connects to the cassette; a blue tube 457 mm long on one side connects to the cassette, on the other side ends with a Luer connector, which provides a connection to a disposable tube (patient tube, not included in the delivery) going into the joint cavity; a cassette in the form of a plastic rectangular box connected to a transparent and blue tubes, has a mechanism for supplying fluid in the form of an impeller rotating by means of a magnetic drive from the pump, a fluid flow pressure sensor and a system of attachments for fixation in the pump.

Principle of operation: the cassette is fixed in the pump. A transparent tube is connected to an irrigation bag/package with liquid. The blue tube is connected via a Luer connector to the patient's tube going into the joint cavity. The pump is activated, which drives the impeller inside the cassette, which ensures the translational movement of fluid from the irrigation bag / bags into the joint cavity. The outer diameter of each tube is 8.89 mm. The size of the cassette (DhVhSh) 115×88.6×30.2 mm. The product is used only for one operating day.

The product comes in individual sterile packaging of three pieces in a cardboard box.

GRI 1 and 6

A sterile disposable surgical device is used in surgery by endoscopic overlay during operations in the gastrointestinal tract (GIT) for the purpose of applying endoscopic marks; hemostasis for bleeding from mucous membrane defects < 3 cm, bleeding ulcers, arteries < 2 mm in diameter, polyps < 1.5 cm in diameter, diverticuli of the colon; as an additional method of closing perforative holes of the gastrointestinal tract < 20 mm, for which conservative treatment is possible.

Full description

The device is located in a cassette that has a gripper head and a port for insertion. The device consists of a tube, connector and jaws, which are made of stainless steel. The length of jaws is 9 mm, the angle of bending of the distal part of jaws is 90 °. The device is installed at the site of damage using endoscopic instruments. To the connector of the device is connected the distal part of the disposable reboot applicator clips (not included in the delivery), which controls the device and its installation on the damaged area of tissue.

At the installation site of the device, the cessation of bleeding is carried out by mechanical compression of damaged tissues with the jaws of the device. The device thanks to the shape of jaws is fixed on the edges of the wound, reduces them, and completely stops bleeding. Subsequently, epithelial tissue is formed at the installation site of the device, while excess dead tissue together with the device is rejected by the body for 40 days and the device leaves the gastrointestinal tract naturally. The device does not perform the function of replacing a defective or non-working body part.

The device comes in a sterile package of 40 pcs.

GRI 1 and 6

The product is a T-shaped intrauterine therapeutic system with the content of the active substance levonorgestrel 52 mg (CAS No. 797-63-7), which, after introduction into the uterine cavity, releases the hormone levonorgestrel directly into the uterus (release of levonorgestrel 20 μg / 24 hours).

Full description

The intrauterine system consists of a white reservoir of hormone, coated with a membrane, mounted on a vertical part of a T-shaped body made of low density polyethylene with 20-24% barium sulfate. A double blue thread is attached to the loop on the T-shaped housing to remove the system. The vertical part of the T-shaped housing and the filament are placed in a conductor tube, which is graded from 5 (top) to 12 (bottom) indicating units of measurement (“cm”). On the conductor tube there is a movable index ring of blue color.

The handle of the conductor contains a blue runner designated by the number "1" and a green runner designated by the number "2". The body of the handle of white color is indicated by the number "3". The thread is located inside along the entire length of the device for insertion and comes out from the rear end of the handle. It is used in adult women over 18 years of age for contraception (prevention from pregnancy), treatment of idiopathic menorrhagia (heavy menstrual bleeding). Release form: 1 IUD together with a device for insertion in a sterile tray of thermoformable film with instructions for use and a memo for the user in a cardboard pack with control of the first opening.

GRI 1 and 6

A set of manual surgical, orthopedic instruments made of stainless steel is used in professional practice by surgeons to perform surgery for the installation of cage, expanding interbody cage and transforaminal interbody (not included in the set) to stabilize the lumbar spine and (or) lumbar-sacral spine in the treatment of osteochondrosis, degenerative spondylolisthesis, pseudoarthritis, degenerative scoliosis and spinal deformity in adults.

Full description

The tools of the set are placed in a stainless steel container, laid in special fixing staff places (plugs). The kit consists of the following tools: straight curette; left-handed retractor; right-handed retractor; Impactor finish 2 pcs; hammer; cage insertion tool; medium curette strutholder fitting (test reusable cage) 7 mm; fitting (test reusable cage) 8 mm; fitting (test reusable cage) 9 mm; fitting (test reusable cage) 10 mm; fitting (test reusable cage) 11 mm; fitting (test reusable cage) 12 mm; expander 13 mm; extender 12 mm;

T-shaped grip-limiter; strut holder; container for placing test reusable cages; container with a tool lid. Tool handles are made of silicone or polyphenyl sulfon. During the operation, the surgeon independently decides on the sequence of use of all tools of the set based on the specific situation within the operation on a particular patient. The container with a set of tools is supplied in non-sterile form, packed in a cardboard box with a label containing information about the name of the goods, article number, manufacturer.

GRI 3(b) and 6

A set of manual surgical, orthopedic instruments made of stainless steel is used in professional practice by surgeons for the purpose of performing an operation of internal spinal fixation, installing implants (not included in the set), preparing a hole in the bone for installing a screw, a screw holder and creating the correct sagittal balance of the spine in the treatment of osteochondrosis, spinal stenosis, scoliosis, kyphosis, injuries, fractures, etc.

Full description

The set tools are placed in a stainless steel container, stacked in three trays in special fixing staff places (plugs). The trays are consistently installed in three levels. The kit consists of the following instruments: a straight probe; a curved probe; a probe/buge (straight); a probe/buge (curved); a shile; a gauge 5 mm, a gauge 6 mm; a gauge 7 mm; a mandren type 1; a mandren type 2; a screwdriver with a torque limiter (12 Nm); T-shaped grip-limiter; nut tighter from 1 pc to 10 pcs; screwdriver (pin); screwdriver for connectors; polyaxial screwdriver; device for tightening the nut; adapter T-20 on the screw; monoaxial screwdriver; rod flexor; pusher; persuader; hex-sided key; counter-key; holder of the rod; manipulator; finish left-sided tool for the rod; finish right-sided tool for the screw; rod for placement of the screwdrivertor; rod for placing the screwdrivertor 3; rod for placing the screwdrivertor;

Tool handles are made of silicone or polyphenyl sulfon. During the operation, the surgeon independently decides on the sequence of use of all tools of the set based on the specific situation within the operation on a particular patient. The container with a set of tools is supplied in non-sterile form, packed in a cardboard box with a label containing information about the name of the goods, article number, manufacturer.

GRI 3(b) and 6

Помпа микроинфузионная одноразовая представляет собой стерильное медицинское изделие, предназначенное для одноразового применения квалифицированным медицинским персоналом для проведения управляемой инфузии при проведении контролируемой пациентом анальгезии (с возможностью переключения скоростей, остановки инфузии) и специально предназначено для непрерывного введения базальных и болюсных доз лекарственного препарата.

Full description

Скорость инфузии (1,2,3,4,5,6,7 мл/ч) устанавливается с помощью извлекаемого ключа управления (в комплектацию не входит). Не используется для трансфузии крови, её компонентов, препаратов белкового ряда, жировых эмульсий. Состоит из следующих компонентов: полимерного корпуса, силиконового резервуара, соединенного с плунжерной системой, инфузионной линии, зажима, порта заполнения, болюсного модуля с фиксирующим ремнем, модуля переключения скоростей для регулировки скорости потока лекарственного препарата, инфузионного фильтра, штырькового коннектора с гидрофобной заглушкой.

GRI 1 and 6

What import requires

Russian bans and restrictions

May apply

Whether a measure applies to your goods is determined by the provisos in the “code” column. Measures are taken from the register as of the date the act was published; the act is named on every line

  • 9018 (за исключением 9018 31 900 1, 9018 49 100 0, 9018 50 900 0, 9018 90 100 0)Out of RussiaProhibited

    Отдельные виды товаров — временный запрет на вывоз

    Приборы и устройства, применяемые в медицине, хирургии, стоматологии или ветеринарии, включая сцинтиграфическую аппаратуру, аппаратура электромедицинская прочая и приборы для исследования зрения

    Постановление Правительства РФ от 09.03.2022 № 311 — until Dec 31, 2027

  • 9018 (за исключением 9018 31 900 1, 9018 49 100 0, 9018 50 900 0, 9018 90 100 0)Out of RussiaPermit required

    Товары медицинского назначения

    Приборы и устройства, применяемые в медицине, хирургии, стоматологии или ветеринарии, включая сцинтиграфическую аппаратуру, аппаратура электромедицинская прочая и приборы для исследования зрения

    Постановление Правительства РФ от 09.03.2022 № 312 — until Dec 31, 2027

Veterinary and sanitary control

Goods fall under supervision by their type and characteristics

  • Sanitary and epidemiological supervision (control)

    rule for the whole chapter 90
    Продукция машиностроения и приборостроения производственного, медицинского и бытового назначения, кроме запасных частей к транспортным средствам и бытовой технике (за исключением контактирующих с питьевой водой и пищевыми продуктами); Средства индивидуальной защиты; Иная продукция (товары), в отношении которой одним из государств – членов Евразийского экономического союза введены временные санитарные меры

    Решение Коллегии Евразийской экономической комиссии от 17.09.2019 № 154

Conformity assessment

May apply

Whether the goods fall under a regulation depends on their name and characteristics. Check them against the list

  • ТР ТС 032/2013Safety of equipment operating under excessive pressure
    • Барокамеры (кроме одноместных медицинских) — declaration of conformity or certificate of conformity
  • Постановление № 2425Единый перечень продукции: сертификация и декларирование в РФ
    • Инструменты вспомогательные, принадлежности и приспособления разные, металлические шурупы для костей (применяемые в ветеринарии) — declaration of conformity (part of the heading) · ГОСТ 19126-2007, ГОСТ Р 52770-2023

    С 1 сентября 2022 г. декларация о соответствии такой продукции принимается при наличии у изготовителя (продавца) протокола исследований (испытаний) и измерений, проведенных аккредитованной в национальной системе аккредитации испытательной лабораторией (центром).

Checked: the consolidated list of Government Decree No. 2425 and the lists of 42 technical regulations out of 52 adopted. The others have no list by HS code, so see the full list of regulations.

How it is done in practice

Valid documents in the EAEU unified register for subheading 9018 90: certificates 3, declarations 1,718.

By technical regulation
ТР ТС 020/20111,687ТР ТС 004/2011397ТР ЕАЭС 037/201635ТР ТС 010/201120ТР ТС 032/20132
Schemes
1д1,1372д2694д1683д1393с3The letter after the scheme number shows the form: certification or declaration of conformity.
Most active certification bodies
Бишкекский Центр испытаний сертификации и метрологии при Центре стандартизации и метрологии при Министерстве экономики Кыргызской РеспубликиООО «Центр Сертификации Стандарт»Орган по сертификации продукции Общества с ограниченной ответственностью «Центр Сертификации Стандарт»
Manufacturers outside the EAEU
China536Switzerland207Germany179United States149Italy92South Korea88

Manufacturers of these goods →Check a supplier’s document by its number →

EAEU non-tariff regulation

Unified list of non-tariff measures (EEC Board Decision No. 30 of 21.04.2015). List entries selected by code

  • 2.16licensing regimeon import and exportpartial match

    Радиоэлектронные средства и (или) высокочастотные устройства гражданского назначения, в том числе встроенные либо входящие в состав других товаров

    1 list entry

    включающие в себя высокочастотные генераторы

Tariff preferences

The code is on the EAEU list of preferential goods: for goods originating in a beneficiary country the duty is lower

Least developed countrieszero rate0%
46 countries

Burkina Faso, Guinea, Eritrea, Congo - Kinshasa, Timor-Leste, Afghanistan, Mauritania, Yemen, Cambodia, Lesotho, Laos, Bangladesh, Nepal, Tanzania, Palestinian Territories, Angola, Benin, Burundi, Haiti, Gambia, Guinea-Bissau, Djibouti, Zambia, Kiribati, Liberia, Madagascar, Malawi, Mali, Mozambique, Niger, Rwanda, Senegal, Myanmar (Burma), Sudan, Sierra Leone, Uganda, Chad, South Sudan, Syria, Solomon Islands, Comoros, Togo, Tuvalu, Ethiopia, Somalia, Central African Republic

The preference requires a document of origin and compliance with the direct consignment rule; customs checks the right to it at declaration.

Payments on import

Duty for this code: 0%. On top of the duty, on import into Russia you pay VAT of 22% (unless the goods are VAT-exempt) of the customs value including the duty (Article 160 of the Tax Code) and the customs processing fee — a fixed amount by value band. Customs value: the price of the goods, delivery to the border, local costs.

Import VAT in EAEU countries

  • Russia22%
  • Kazakhstan16%
  • Belarus20%
  • Armenia20%
  • Kyrgyzstan12%

Standard rate; each country has reduced rates and exemptions for some goods. The duty for the code above is the union one, the same for all

May be VAT-exempt

The exemption under list No. 1042 applies if the goods match the description and are registered as a medical device:

  • 9018 — Инструменты механизированные 94 3100 (инструменты сшивающие; инструменты режущие с приводом; инструменты механизированные прочие)
  • 9018 — Инструменты режущие и ударные с острой (режущей) кромкой 94 3300 (инструменты однолезвийные; томы; инструменты выкусывающие; ножницы (медицинские); инструменты однолезвийные скоблящие; инструменты многолезвийные с вращением вокруг собственной оси (сверла, фрезы, боры) и прочие)
  • 9018 — Инструменты оттесняющие 94 3400 (расширители; инструменты оттесняющие (зеркала, шпатели); инструменты разделяющие; инструменты извлекающие)
  • 9018 — Инструменты многоповерхностного воздействия (зажимные) 94 3500 (зажимы; пинцеты (медицинские); щипцы зажимные; держатели; инструменты раздавливающие)
  • 9018 — Инструменты зондирующие, бужирующие 94 3600 (зонды; бужи; катетеры; трубки, канюли) (за исключением 9018 31)
  • 9018 — Наборы медицинские 94 3700 (наборы для сердечно-сосудистой и абдоминальной хирургии; наборы травматологические; наборы оториноларингологические; наборы офтальмологические; наборы стоматологические; наборы акушерские, гинекологические, урологические; наборы нейрохирургические; наборы общего назначения)
  • 9018 — Приборы для функциональной диагностики измерительные 94 4100 (комплексы аппаратуры для передачи электрокардиограмм по телефонному каналу; кардиокомплексы; приборы для измерения биоэлектрических потенциалов; средства измерения массы, силы, энергии, линейных и угловых величин, температуры; приборы для измерения давления; приборы для измерения частоты, скорости, ускорения, временных интервалов и перемещений; приборы для исследования звуковых колебаний в органах человека; приборы для измерения объема и газового состава вдыхаемого и выдыхаемого воздуха и крови; генераторы сигналов диагностические; измерительные установки, комплексы, сигнализаторы, регистраторы, индикаторы)
  • 9018 — Приборы и аппараты для диагностики (кроме измерительных). 94 4200 (диоптриметры); приборы эндоскопические и увеличительные; аппараты рентгеновские медицинские диагностические; приборы радиодиагностические; приборы офтальмологические; приборы для аускультации (выслушивания); очки корригирующие (для коррекции зрения) <***>, приборы для функциональной диагностики прочие)
  • 9018 — Приборы и аппараты для медицинских лабораторных исследований 94 4300 (анализаторы состава и свойств биологических жидкостей медицинские; приборы и аппараты для санитарно-гигиенических и бактериологических исследований измерительные; приборы и аппараты для клинико-диагностических лабораторных исследований, кроме анализаторов; приборы и аппараты для санитарно-гигиенических и бактериологических исследований, кроме измерительных; комплексы и комплекты (наборы) для клинико-диагностических лабораторных исследований; комплексы и комплекты (наборы) для санитарно-гигиенических и бактериологических исследований; приборы и аппараты вспомогательные для клинико-диагностических, санитарно-гигиенических и бактериологических исследований общего назначения)
  • 9018 — Приборы и аппараты для лечения, наркозные. Устройства для замещения функций органов и систем организма 94 4400 (приборы и аппараты для электролечения низкочастотные; аппараты для электролечения высокочастотные и квантовые; приборы и аппараты для воздействия ультрафиолетовыми и инфракрасными лучами; эндоскопы для лечения; аппараты водолечебные и бальнеологические, механотерапевтические; приборы и аппараты радиотерапевтические, рентгенотерапевтические и ультразвуковые; аппараты ингаляционного наркоза, вентиляции легких, аэрозольтерапии, компенсации и лечения кислородной недостаточности; аппараты вакуумно-нагнетательные, для вливания и ирригации; аппараты и устройства для замещения функций органов и систем организма; приборы и аппараты для лечения другие)
  • 9018 — Оборудование для кабинетов и палат, оборудование для лабораторий и аптек 94 5200 (термостаты электрические; установки стоматологические универсальные; оборудование кабинетов и палат; оборудование стоматологическое, зубопротезное, оториноларингологическое; оборудование рентгенологическое, радиологическое и равматологическое; оборудование лабораторное и аптечное; оборудование и агрегаты медицинские разные)
  • 9018 — Специальные средства для самообслуживания и ухода за инвалидами (в том числе подушки и матрацы профилактические, противопролежневые и ортопедические, кровати медицинские с подъемными приспособлениями, фиксаторами, стулья и кресла функциональные, на колесиках, со съемными элементами, поручни, оборудование для подъема и перемещения, специальные приспособления для пользования средствами личной гигиены), специальные средства при нарушениях функции выделения (в том числе уропрезервативы, мочеприемники, мешки для сбора мочи, катетеры, ремни для крепления мешков для сбора мочи, вешалки-крючки для крепления мочеприемников, калоприемники, мешки, пластины и фильтры к калоприемникам, кольца защитные и эластичные полукольца, стержни для стомы, очистители для кожи, нейтрализаторы запаха, анальные тампоны, тампоны для стомы, ирригационные системы и рукава для стомы, пояса крепления калоприемников)
  • 9018 90 840 9 — Инструменты колющие <**> 94 3200 (иглы стержневые; иглы трубчатые (инъекционные); скарификаторы, перья; перфораторы, троакары)

The right code is in the HS code search.